Bathroom

Paul Yates Electrical

  Showers

 

Electric shower     

 

 

 

 


Connected direct to the mains fusebox, this type will supply unlimited quantities of water on demand.
One limitation with the lower power models is the volume of water delivered during winter months.

  • Showers are available at:
  • 7KW
  • 8KW
  • 9KW
  • &  10.8 KW  ratings.
showerblack.jpg (13477 bytes),Paul Yates Electrical is a small domestic and commercial electrical contractor based in the West Yorkshire town of Keighley. paul yates, electrical,electrics, contractor, domestic,electrican, iee,regulations, engineer, bd21, west yorks,
 west yorkshire, yorkshire, keighley, bingley,skipton,dales,electricity,energy,yeb,rcd,mcb,socket, qualified,skipton,pye, sockets,
  • All these showers will supply hot water but the
     quantity supplied by a 7KW shower is noticeably less than a 8KW shower. In the summer months a 7Kw will suffice but as the colder water intake in winter produces a cooler water jet a more powerful heater will be preferred.
     
  • All electric showers must be supplied by a dedicated cable
  • This cable will be either 6mm sqd or 10mm sqd csa
  • If your shower circuit is protected by a re-wireable type fuse, then it should be replaced with either a cartridge type or a MCB
  • For details of fuses & MCB's see the Fusebox page also see fuses

  45A pull switch